Systems / Outside / Air conditioning
Air conditioning
The undermount ICEBOX: condenser above the hitch, compressor under the floor.
Outside, inside, lines, then an AC shop charges it. The drawing builds up as you scroll.
Build
Every step in order. Scroll and the drawing follows: it builds up to the step you are on and lights what that step adds.
Settle step 1
1
Settle the compressor spot and the corner
- Underneath (quiet, longer hose) or on the garage floor (kit hoses, noise inside).
- Which corner the evaporator takes, and whether the lines go through the floor or the back wall.
Outside steps 2 to 3
2
Condenser above the hitch
- Almost flat between the frame rails, on its universal brackets, the rock guard below.
- Turn it so the SMALL port is LOWER than the large port, or oil collects in it and starves the compressor.
- Clear air under it: at least 4 in to the spare.
Caution Small port low, large port high. The manual is firm on this.
3
Compressor box underneath
- Through-bolted to the body crossmembers with #8 bolts and washers, ahead of the condenser.
NeedsReady: everything is in hand
Compressor, in its stainless boxhave itInside steps 4 to 5
4
Evaporator high in the garage corner
- Mounted flat so its pan drains; return air can reach its front.
- Blower turned to blow along the ceiling; ducts 4 ft or less each.
5
Control hub and control
- Dry, close to the compressor's cable reach (5 or 7 ft), with the control on the wall.
Lines steps 6 to 8
6
Hoses and the dryer
- Hose 1 compressor to condenser top, 2 condenser bottom to the dryer IN, 3 dryer to the evaporator's lower port, 4 its top port back to the compressor.
- Dryer upright, sight glass visible. Insulate hose 4. Grommets through every hole.
7
Condensate drain
- 3/8 tube from the evaporator down through the floor to outside, falling all the way.
NeedsReady: everything is in hand
Condensate drain, 3/8 IDhave it8
Power
- The main cable from the battery bus through a breaker to the hub, sized with the electrical plan.
NeedsWaiting on 1 of 1
Main power cable and breaker, about 55 ATBDCommission step 9
9
Evacuate and charge
- An AC shop pulls a vacuum, leak checks and charges it.
Caution The compressor is pre-filled with PVE oil. Do not let any other oil into the system.
NeedsWaiting on 1 of 1
Evacuate and charge, by an AC shopTBD