Electrical build
The order of work for the whole electrical system: the battery bank and its main fuse, one chassis bond, solar, alternator and shore charging, the MultiPlus and the AC panel, the 12 V branch circuits to the control box, then dead tests, first power and setup in VictronConnect.
Order list6 now, 13 after a check, 9 not yet
Prices as last seen; check before paying. "After a check" names the check in the step list.
Order now6
3 to 30 A for the WFCO's 15 DC positions, with spares in the glovebox.
2/0 and 1/0 lugs want a proper hex crimp, not a hammer crimper.
Sized to each cable and each stud: M8, M10, 3/8 and 5/16.
Every big lug in this guide has a number. Insulated, so a dropped socket can't bridge the bank.
For commissioning: reads each charger's current without breaking a cable.
Salt air: grease every connection. Washboard: nothing unclamped. Labels at both ends.
After a check13
Alternator charging, up to 50 A out each. Three draw about 165 A from the truck, close to what Ford allows at its connection points (three 60 A CCPs, about 180 A total, on dual-AGM trucks). The count is decided in step 2.
Only if step 1 finds one Lynx in the truck. The diagram splits the loads across two.
Next to the bank positive, before the switch. Check what is fitted now (step 1). Victron's Lynx Class-T Power In takes two Class T fuses (225 to 400 A) and bolts to the M10 Lynx line.
ABYC wants each battery positive fused close to its post. With three in parallel that usually means a terminal fuse on each link. Ask Battle Born what they want for three GC3s before buying.
Where the three equal links meet. Rated above the 400 A main.
Battery links, main runs, the chassis bond and the MultiPlus pairs. Lengths in the cut list are ASSUMED; buy after step 3 measures them.
The MultiPlus-II manual's table for runs of 0 to 5 m: two 1/0 per pole, 400 A fuse. Jeff's diagram shows 2/0; one 2/0 is not two 1/0. Check what is on it now.
Orion XS manual: 60 to 70 A. One at the input bus per Orion, and one on each output at the Lynx.
At the cab end of the alternator cable that is already run, within 7 in of where it connects. Sized to that cable and to Ford's connection point: the Body Builder Layout Book has the points for this truck.
MPPTs 70 to 80 A each (manual). Orion outputs 60 to 70 A. WFCO feed 80 A ASSUMED, check its label. A/C per the Cruise N Comfort manual. The MultiPlus's 400 A only if the Lynx manual allows that size.
The DC branch circuits. working/electrical-bom.html estimates 250, 100, 100 and 25 ft. Buy against measured runs, step 3.
Between the shore inlet and the MultiPlus AC-in. Its manual: the AC input must be protected by a fuse or breaker of 50 A or less, downsized to the supply. The current plan does not show one.
Two GFCI (galley, bath), two or three standard (lounge, bed), about 50 ft of 12/2 with ground. Fix the outlet spots first.
Have it10
The bank: 810 Ah, about 10 kWh. Maker's listing: 22.83 x 7.09 x 13.15 in, about 80 lb, 300 A continuous each, terminals 9 to 11 ft-lb. Owned per context.md; not in receipts/README.md.
Manual battery switch, already wired, and it stays (control-panel.html). Read its continuous rating off the label in step 1.
Already on the bank. Check which current rating it is: on the 500 A model the M10 bolts take 21 Nm at most.
context.md lists one Lynx Distributor. Jeff's diagram draws two.
Installed and charging, not yet networked. 860 W nominal PV at 12 V each; each string is about 700 W.
Installed and wired 2026-07-14. AC main and branches on one side, 15 DC fuse positions on the other: thirteen 20 A and two 30 A (product sheet). There is no converter inside it: WFCO's converters are separate deck-mount units that plug into its back.
The 3000 W inverter/charger in context.md. Confirm the label says this model: every number on this page for it comes from that model's manual.
Six panels in two strings of three on Rack Denise. The breakers stay the service disconnect.
Not yet9
Undecided (electrical.html). Step 18 waits on it.
OPEN until the full lighting map (STATUS, 2026-09-30). An-Penta-Deca: 15 PWM channels, 5 A each, 30 A total, ESP32, 12 to 48 V, not on Amazon. Per-zone: a Gledopto ESP32 PWM per zone.
8 relays for the ESP-switched circuits; its inputs read the rockers. Channel count waits on the lighting map.
Only if the A/C's own control line can't switch it, which is unverified. 0 mA hold, manual override.
The panel face; final once the 9 vs 10 in face width is set.
Four: lounge, bed, galley, panel face. One model for all, not chosen.
Rockers and the rotary to the ESP at the back of the box.
Lets the H2O rocker switch the Isotemp element branch.
Cut list24 parts
Inches. "Field-fit" means cut to the thing it meets, on the day.
| part | stock | qty | size | |
|---|---|---|---|---|
| Equipment board, bulkhead | 3/4 plywood | 1 | 66 x 34 | screwed into the bulkhead framing, not the skin |
| Equipment board, driver wall | 3/4 plywood | 1 | 23 x 26 | into the 8020 with T-nuts |
| Equipment board, passenger wall | 3/4 plywood | 1 | 23 x 40 | carries the MultiPlus (42 lb): into the 8020 |
| Battery links + and - | 2/0 tinned, red and black | 6 | 54 13/16 each | ALL THE SAME LENGTH: cut to the longest route, coil the short ones |
| Main positive | 2/0 red | 3 | 93 7/16 in (~8 ft) total | bus to Class T, Class T to BEP, BEP to Lynx B |
| Main negative | 2/0 black | 2 | 80 15/16 in (~7 ft) total | bus to shunt battery side, shunt system side to Lynx A |
| Lynx link | 2/0 red and black | 2 | short | or butt the two Lynx together and skip it |
| Chassis bond | 2/0 ASSUMED, green or black | 1 | 79 1/16 in (~7 ft) | match the alternator cable: it may carry the Orion return |
| MultiPlus case ground | 6 AWG ASSUMED | 1 | 100 11/16 in (~8 ft) | check the gauge in the MultiPlus manual |
| MultiPlus DC | 1/0 red and black | 4 | 60 11/16 in (~5 ft) per positive | two per pole (manual, 0 to 5 m) |
| MPPT outputs | 6 AWG red and black | 4 | 88 1/2 in (~7 ft) each, longest | run in pairs, + and - together |
| Orion outputs | 6 AWG red and black | 6 | 58 9/16 in (~5 ft) each, longest | per Orion; 4 AWG if any run goes over 5 m |
| Orion inputs | 6 AWG red | 3 | ~12 in each | input bus fuse to the Orion |
| Alternator positive | as installed (2/0 ASSUMED) | 1 | 218 7/8 in (~18 ft) | ALREADY RUN through corner A; read the gauge and length off it |
| WFCO DC feed | 6 AWG red and black | 2 | 121 3/4 in (~10 ft) | fused at the Lynx |
| A/C feed | 4 AWG red and black | 2 | 20 5/16 in each | position ASSUMED; installed already? |
| PV, breaker to MPPT | PV wire | 2 | ~12 in | polarity marked before cutting |
| Shore cable | 10/3 | 1 | 11 5/8 in | inlet to breaker to AC-in; longer if the inlet moves |
| AC out to WFCO | 10/3 ASSUMED | 1 | 9 9/16 in | see the notes: protection at the MultiPlus end |
| AC branch, Isotemp | 12/2 with ground | 1 | 56 1/4 in (~5 ft) | through the bulkhead into the core pocket |
| AC branch, galley and lounge | 12/2 with ground | 1 | 328 1/2 in (~27 ft) | own loom, 3 in above the DC trunk |
| DC trunk to the control box | duplex bundle | 1 | 300 9/16 in (~25 ft) | every circuit its own home run; measure each |
| Passenger branch | 14/2 duplex | 2 | 85 15/16 in (~7 ft) | pump and chest fridge |
| Light runs | 18 AWG 5-core | per zone | 136 3/8 in (~11 ft) | HELD with the controller |
Plan and checksteps 1 to 4
- Most of the power bay is already in the truck. Before buying anything, photograph every connection and write down what is there.
- For each cable: its gauge (printed on the jacket), both ends, and the fuse protecting it, if any. Label both ends now.
- Count the Lynx Distributors (one or two). Read the BEP switch label for its continuous rating, and the SmartShunt's current rating.
- Find the main fuse. Is there a Class T within reach of the bank positive? A MEGA or ANL is not a substitute at an 810 Ah lithium bank.
- Read the MultiPlus label: it should say MultiPlus-II 12/3000/120-50. Count its DC cables per pole (the manual wants two 1/0).
- Find where the WFCO actually is, and check that no deck-mount converter is plugged into its back.
- Note how the three batteries are joined today (context.md says daisy-chained) and where the system negative meets the chassis.
Tip Mark each line on this page 'done' where the audit shows the step is already right. Only redo what fails a step's check.- Orion count, 2 or 3. Three give up to 150 A while driving but draw about 165 A from the truck, close to Ford's limit at its connection points. Two give 100 A and leave margin. The alternator cable's gauge (step 1) can decide it.
- The chassis bond. Short, through the garage floor to the frame (drawn), or the long run to the cab that exists now through corner A, the wet room.
- The shore inlet: SmartPlug or Marinco. Its position sets the AC input run.
- The WFCO's home: Jeff's diagram has it on the passenger wall, the BOM assumes the rear driver corner.
- How the MultiPlus output is protected. Its manual asks for a GFCI breaker in series with the output; the settled plan is a plain 30 A main with GFCI at the wet outlets. Not re-opened here, but confirm it is still the plan knowing what the manual says.
Tope Five answers, then the garage can be built in one pass.- Tape the garage: depth bulkhead to door opening, width, and the height under the first shelf. This page uses the plan's derived 27 3/16 deep, never taped.
- Cut cardboard to every box size on the Plan tab and tape them up. Chargers sit beside the batteries, never directly above one (Orion XS manual).
- Leave 10 cm (about 4 in) all round each Orion, and the clearance the MPPT manual asks for.
- Tape a string along every big run and measure it. Then measure each branch circuit home run from the WFCO to its load.
- Mark where cables cross a bulkhead or a wall: each crossing gets a grommet.
Caution Victron's Orion XS manual: mount close to the battery but never directly above it. Jeff's diagram draws the chargers over the bank; the page moves them aside.- Now: fuse assortment, hydraulic crimper, lugs and heat shrink, torque wrench and insulated sockets, clamp meter, grease, loom and labels.
- After the audit and the measured runs: cable by the measured lengths, Class T and terminal fuses, bus bars, the Orions, the second Lynx if needed.
- Held: inlet, lighting controller, relay board, rockers, USB-C, signal cable. Each one names what it waits on in the Order list.
Make it safesteps 5 to 6
- Shore cord unplugged. MultiPlus switched off. Engine off and key out, so the alternator is dead.
- Both PV breakers off. In daylight the panels are still live up to the breaker: cover them or work at night if you open PV wiring.
- BEP master off. Then prove it: meter across the Lynx + and - reads 0 V, and across the bank bus bars reads the full bank voltage you are still working next to.
- Rings and watch off. Insulated tools. One hand on the work where you can.
Caution Opening the BEP does not make the bank safe. Three 270 Ah lithium batteries will weld a spanner across their terminals. Treat every battery post and bus bar as live, always.- Crimp one 2/0 lug on a scrap and cut it in half: the strands should be one solid mass with no gaps. Pull-test another by hand.
- Adhesive heat shrink over every lug, so salt air can't wick up the strands.
- The torques in this guide: Battle Born terminals 9 to 11 ft-lb (maker's listing), SmartShunt 500 A M10 at most 21 Nm, Lynx M10 per its manual's table for your serial (33 Nm on current units, 17 Nm before serial HQ2340), MultiPlus DC 12 Nm (M8), MPPT terminals 2.4 Nm, Orion XS 4.5 Nm on 6 AWG and 5.6 Nm on 4 AWG.
- Anything without a number here: the label or the manual, never feel.
Tip Write the torque on a strip of tape beside each device as you go. Step 33 re-checks all of them.
Battery banksteps 7 to 12
- 3/4 ply on the bulkhead, the driver wall and the passenger wall, screwed into structure: 8020 with T-nuts on the walls, the bulkhead's framing behind.
- The passenger board carries the MultiPlus, 42 lb on a washboard road: through-bolt it.
- Battery hold-downs on the floor: a stop block on each side and a strap over each battery into the floor. About 80 lb each must not move in a hard stop.
Tope Rubber isolation under each battery, and stainless hardware everywhere. Salt air and washboard are the threat model.- One GC3 along each wall: driver side, passenger side and the bulkhead (this page's reading of Jeff's diagram).
- Terminals to the front, where a socket can reach them from the barn doors.
- Charge all three to full on their own before joining them, so they start at the same voltage.
- Strap them down. Fit the terminal covers until each cable lands.
Caution Never join batteries at different states of charge: the full one dumps current into the empty one through the link.- Positive and negative bus bars on the bulkhead board, above the middle battery.
- Six links, 2/0, every one the same length (about 54 13/16 on this layout). Coil the short runs rather than cut them short: equal links share the load.
- Negative links first, then positive. If Battle Born approves terminal fuses, they go on the positive links at the battery end.
- Battle Born terminals 9 to 11 ft-lb. Grease, then the covers back on.
Tip This replaces the daisy-chain in context.md. If the audit found it daisy-chained, take the bank + and - from opposite ends at least.- Positive bus to the 400 A Class T fuse, as short as it can be: this fuse protects everything downstream, the 2/0 included.
- Class T out to the BEP 400 A switch, then the switch out to Lynx B.
- Leave the fuse OUT until step 31.
- Check the switch and the fuse against the worst case: inverter flat out (about 300 A at 12 V) plus the A/C (45 A) plus the DC panel.
Caution A 400 A fuse below that worst case can nuisance-blow on a hot day with everything on. Size from the audit, don't guess.- Negative bus to the SmartShunt's BATTERY MINUS side. Its SYSTEM MINUS side to Lynx A.
- Nothing else may land on the battery side of the shunt: every load and charger must go through it, or the state of charge is wrong.
- SmartShunt 500 A: 21 Nm at most on the M10 bolts. Its small red wire goes to the battery positive with its own inline fuse (in the box).
- Mount both Lynx Distributors on the driver wall board. Join them with the 2/0 pair, or butt them together on their own bus if there is room.
- Lynx A takes the Orions, the A/C and the chassis bond; Lynx B takes the main feed, the MPPTs and the WFCO feed (Jeff's diagram).
- Torque per the Lynx manual's table for your serial number. Fuses go in later, one circuit at a time.
Groundstep 13
- The Unicell box is not bonded to the chassis, so system negative needs one deliberate bond to the frame.
- Drawn: a stud through the garage floor into the driver frame rail, about 25 in in from the driver wall. Clean to bare metal, star washer, sealed on both sides.
- Size it to match the alternator cable: the Orion XS is common-negative, so the alternator's return current can flow through this bond.
- The MultiPlus case ground goes to the same point: its manual says a mobile install must bond the case to the chassis.
Caution electrical.html says 2 to 4 AWG for the bond. That is too small if it also carries the Orion return, about 165 A with three. Decide in step 2.
Charge sourcessteps 14 to 16
- Both SmartSolar 150/60s on the bulkhead board, beside the batteries, not over them.
- Battery side first, always: 6 AWG to Lynx B, each on a 70 to 80 A fuse (the manual's range). Terminals 2.4 Nm.
- Leave the fuses out until step 31.
Caution Victron: connect the battery before the PV, and disconnect the PV before the battery. PV first can damage the charger.- Before landing PV: read the panel label's Voc. Three in series on the coldest morning must stay under 150 V absolute (145 V to start). Cold raises Voc.
- Each string down through the roof gland to its own breaker, then to its MPPT. Breakers OFF.
- Check polarity on the meter at the breaker, with the breaker off, before the last lug lands. 2.4 Nm.
Caution PV is live whenever there is light, and DC arcs don't put themselves out like AC. Never open a PV connection under load.- Two or three Orion XS on the bulkhead board, vertical, power terminals facing DOWN, 10 cm clear all round (manual).
- Input bus beside them, one 60 to 70 A fuse per Orion, 6 AWG up to each input. Output: 6 AWG to Lynx A with another 60 to 70 A fuse each. 4 AWG if a run goes over 5 m.
- Terminals 4.5 Nm on 6 AWG, 5.6 Nm on 4 AWG. Cable cover under 0.7 Nm.
- The input bus stays dead until the alternator cable lands, step 25.
Inverter and ACsteps 17 to 20
- Hang it on the passenger board, vertical, with the clearances its manual gives.
- DC: two 1/0 per pole for runs up to 5 m, on a 400 A fuse (manual table). 12 Nm on the M8 nuts with an insulated box spanner.
- Check polarity on the meter before the last lug. Reverse polarity can destroy it, and its internal fuses are not user-replaceable.
- Its capacitors draw a spark on first connection: make the final connection by closing the BEP switch in step 31, not by landing a lug live.
Caution Jeff's diagram shows 2/0. The manual's table says TWO 1/0 per pole. If one 2/0 is fitted, ask Victron or a dealer before running 3000 W through it.- Inlet through the passenger wall (SmartPlug or Marinco, held), 10/3 to a 30 A breaker, then to the MultiPlus AC-in.
- The MultiPlus manual: the AC input must have a fuse or breaker of 50 A or less, downsized to the supply. 30 A here.
- AC terminals take ferrules, 18 mm stripped, 2 Nm at most. Order N, PE, L, left to right.
- Seal the inlet with Sikaflex 291 and a sloped fillet at the bottom (the window lesson).
Caution Shore power can kill. Wire the inlet with the cord unplugged and the cord physically in the van with you.- MultiPlus AC-out-1 to the WFCO's 30 A main, plain, not GFCI (settled decision, electrical.html).
- Neutral and ground stay SEPARATE in the WFCO: no bonding screw or strap. The MultiPlus's ground relay bonds neutral to its case when it inverts.
- Protection at the MultiPlus end: the manual lists AWG 6 minimum for AC-out-1 (rated 50 A, more with PowerAssist). 10 AWG to the WFCO is only safe with a 30 A breaker at the MultiPlus end of it.
- Nothing plugged into the WFCO's converter receptacle: the MultiPlus is the shore charger.
Caution A second neutral-ground bond in the panel puts current on the ground wires and defeats every GFCI downstream.- Isotemp 120 V element: its own breaker (15 A estimated, ac-circuits page), 12/2 with ground through the bulkhead into the core pocket.
- The element thermostat is built in, so the only control is on and off. Later a 12 V coil relay lets the H2O rocker switch this branch.
- Grommet the bulkhead, clamp the run clear of the heater's hot pipes.
Garage feedssteps 21 to 22
- Lynx B to the WFCO's DC input: 6 AWG pair, fused at the Lynx (80 A ASSUMED; check the WFCO label for its DC input rating).
- Lynx A to the Cruise N Comfort: 4 AWG pair on its own fuse, sized from the CNC manual. If it is already wired, check the fuse matches.
- Fuses still out.
- Two WFCO positions straight through the bulkhead on the passenger side: pump 14 AWG on 10 A, CFX3 14 AWG on 15 A (DC circuits table, estimates).
- The pump is one of the two mechanical circuits: its home run loops up through its rocker in the control box (step 28).
- Clear of the fridge's slide travel: nothing mounted or wired in the 35 in it rides out.
Tip Fridges never sit behind a relay that fails open: direct-fused (planning/electrical-control-panel.md).
Forward runssteps 23 to 29
- Open the driver wall cavity from the garage corner to the galley. The trunk runs in it, behind the benches, about 22 in up (ASSUMED).
- Mark where each run leaves the trunk: lounge USB-C, Happijac, galley outlets, the control box riser.
- Keep the AC in its own loom, 3 in above the DC. Nothing in the Happijac's sweep or the bed platform's band.
Tip This step shows the rest of the box in colour once, so the forward runs have something to sit in.- The alternator cable, the system ground and the Wolfbox run already cross the cab wall at corner A, 14 1/2 in along the cab wall into the driver wall.
- Before the shower walls close: smooth-bore conduit, one long sweep (no elbow, the red cable has a big bend radius), a pull string left in.
- A second, empty conduit while it is open. No joints in the sealed section. Labels both ends.
- Pull access stays on the cab side, outside the wet envelope.
Tip The shower guide builds the box over it (shower-build.html, Cable box). This step is only the conduit inside it.- Find where the existing cable connects in the cab: a Ford connection point (CCP) under the driver seat, or the spare B+ post on the second battery (dual-AGM trucks).
- Fuse within 7 in of that connection, sized to the cable. Ford's Body Builder Layout Book has the limits for this truck.
- In the garage it lands on the Orion input bus. Read its gauge: about 165 A over roughly 16 ft wants a heavy cable, 2/0 ASSUMED here.
- Engine detection: the Orion senses a running engine by itself, but a Ford smart alternator can fool it. Wire the L-pin to an ignition-switched feed (over 8 V turns it on) if the voltage method misbehaves.
- Key out while you work. The source end goes on last.
Caution An unfused cable from the truck battery is a fire with nothing to stop it. The source fuse goes in before the cable is ever connected.- 12/2 with ground from the WFCO up the garage corner and forward in the driver wall, its own loom, 3 in above the DC trunk.
- GFCI outlets at the wet spots (galley, bath), standard in the lounge. The air fryer on its own 15 A branch (verify its draw against the 30 A main).
- Breaker sizes are estimates until a sizing pass (ac-circuits page). Every penetration grommeted, every run clamped.
- Each WFCO position gets its own duplex home run, + and - together: lights 16 AWG on 10 A, USB-C 12 AWG on 20 A, Eberspacher 12 AWG on 15 A, control box 12 AWG on 15 A, drink fridge 14 AWG on 15 A (the DC circuits table; estimates until the sizing pass).
- Happijac on one of the WFCO's two 30 A positions (product sheet: thirteen 20 A, two 30 A), 10 AWG.
- Bundle them up the garage corner and forward in the driver wall cavity. Clamp every 18 in or so, grommet every crossing, label both ends.
- Check each run's voltage drop once its length is real: long 12 V runs lose volts fast.
- Three power runs up to the box: the box feed (Ekrano, climate heads, panel USB-C) and the two mechanical loops, pump and ceiling lights, through their rockers.
- One multi-core signal cable for every other rocker and the scene rotary, to the ESP at the back of the box (held).
- Ekrano in the face (7.4 x 4.9), wired to the Victron devices with VE.Direct and VE.Bus cables.
- Leave the A/C thermostat and EasyStart cutouts until the parts are in hand.
Tope The van has to work with every smart part dead. Pump and ceiling lights switch power directly; nothing safety-related depends on the ESP.- Pull the light runs now, while walls and ceiling are open: 18 AWG 5-core per strip zone, fused per zone (lighting.html).
- Ceiling: four main pucks and two task pucks under the uppers (counts decided 2026-08-13, positions indicative).
- Leave every run coiled and labelled at the control box. The controller (QuinLED An-Penta-Deca vs per-zone) waits on the full lighting map.
Tip Pull one spare 5-core to the bed corner. The bed-light chain lands there later.
Test and commissionsteps 30 to 33
- Everything off, every fuse out. Meter on ohms.
- Each big cable: + to - open, + to chassis open. The - to chassis reads near zero only through the one bond, nowhere else.
- AC, with the MultiPlus AC terminals disconnected: hot to neutral, hot to ground, neutral to ground all open in the WFCO.
- Polarity on every lug against the labels. Torque marks on every bolt.
- An insulation tester (500 V) only on cables disconnected at both ends: it destroys electronics.
Caution Find a short now, with a meter, not with the 400 A fuse.- Class T fuse in. Close the BEP: the SmartShunt wakes, the Lynx LEDs come on. Smell, listen, feel every big lug after a minute.
- One Lynx fuse at a time: WFCO feed, then each DC circuit one by one, then the A/C, then the MultiPlus.
- MPPT fuses in, then the PV breakers. Clamp meter on each MPPT output.
- Engine on: Orion fuses in, one at a time, clamp meter on each input and output. Shore plugged in last.
Caution Anything warm to the touch at low current is a bad crimp or a loose lug. Stop and redo it.- SmartShunt: battery capacity 810 Ah; charged voltage, tail current, Peukert and charge efficiency from the lithium section of its manual.
- MPPTs, Orions and MultiPlus: Battle Born's published LiFePO4 settings (no equalisation). MultiPlus AC input current limit 30 A for the shore cord.
- VE.Smart network: the SmartShunt and both MPPTs (the fix in the decision log), so they charge off one voltage. Then check how DVCC on the Ekrano interacts: Victron's docs say which takes priority.
- Ekrano: every device shows up, VRM on, Node-RED later. Name each device after where it sits.
Tip Write every setting down on the electrical page once it works. The next time a unit is swapped in Baja, that list is the setup.- Inverter: run a known 120 V load for 30 minutes (the Isotemp element), clamp the MultiPlus DC cables, feel every lug.
- A/C on high with the inverter loaded: the worst-case current through the main fuse and the BEP.
- Drive an hour with the Orions charging: check the alternator cable temperature at both ends.
- After the first week of washboard: re-torque every big lug to its number, and look for chafe at every crossing.
Notes16
- Sources: Electrical, Control panel, Interior lighting, Appliances, the working pages (battery bank, charge sources, DC circuits, AC circuits, DC routing, BOM), planning/electrical-control-panel.md, context.md, and the makers' manuals linked in the Order list.
- Frame: x forward of the rear doors, y across from the PASSENGER wall, z up. Floorplan X = 168 - x and floorplan Y = 84 - y. Chosen so the drawing looks into the garage from the barn doors.
- ASSUMED: garage depth 27 3/16 (derived on the floor plan, never taped); one battery per wall; every equipment position; the chassis bond point; the A/C position (the old layout drew it high, driver side); the control box station (copied from layout.html); the roof gland; the shore inlet spot; every cable route and length; the Lynx and SmartShunt box sizes.
- CONFLICT, MultiPlus DC cable: the MultiPlus-II 12/3000/120 manual's table asks for 2 x 1/0 per pole (0 to 5 m) and a 400 A fuse. Jeff's diagram shows 2/0.
- CONFLICT, chargers over the bank: Jeff's diagram puts the MPPTs and Orions on the mid wall over the batteries. The Orion XS manual says never directly above the battery. This page moves them beside it; a check fails the page if one sits over a battery.
- CONFLICT, GFCI: the MultiPlus-II 120 V manual says a UL 943 GFCI breaker must be in series with AC-out-1. The settled decision is a plain 30 A main with GFCI at the wet outlets, because GFCI mains nuisance-trip in coastal air. Not re-opened; flagged so it is a choice made knowing what the manual says.
- CONFLICT, AC wire size: the manual lists AWG 6 minimum for AC-out-1 (rated 50 A; with PowerAssist the output can reach 75 A). The plan's 10 AWG to the WFCO's 30 A main is only protected if the 30 A breaker sits at the MultiPlus end.
- GAP: no breaker between the shore inlet and the MultiPlus AC-in on the AC circuits page. The manual requires one, 50 A or less, sized to the supply.
- CONFLICT, bond size: electrical.html says 2 to 4 AWG for the single chassis point. The Orion XS is common-negative, so the alternator's return current can use that bond: size it like the alternator cable.
- CONFLICT, WFCO position: Jeff's diagram has the AC/DC box on the passenger wall; the BOM's lengths assume the DC panel at the rear driver corner.
- Resolved by the WFCO product sheet: of the 15 DC positions, thirteen are 20 A and two are 30 A, so the Happijac's 30 A fits one of the two. The panel's total DC rating is still unread.
- VE.Smart networking (decision log) and DVCC on the Ekrano overlap. Check Victron's docs for which one wins before turning both on.
- Starlink is a Mini (context.md, 2026-08-14). The BOM's 12 to 48 V kit is the standard dish's; check the Mini's DC input on its spec sheet before buying anything for it.
- Battle Born terminal torque (9 to 11 ft-lb) and the GC3 size come from the maker's listing; check the manual in the box. Whether these GC3s are the heated version is not recorded, which matters for charging below freezing in the PNW: check the label.
- Sourcing: Jeff is in Portland. No Home Depot links here, because none came from a homedepot.com search this session; the Amazon links are searches, not item pages. Cable, lugs and fuses are also sold by Portland marine and RV suppliers, not checked.
- Not on this page: the Wolfbox dashcam (its own hardwire kit), the Mac mini power path (blocked on a decision), the Eberspacher (model open).