Installing the Isotemp
Every instruction and every diagram for the Isotemp Slim Square 16, on one page, in the order the work happens. How the engine coolant loop works and why the unit ends up in parallel with the cab heater. Why the heater has two cold connections and what the second one is for. The potable side, the safety valve, the electrics, and commissioning. Pulled from the manufacturer's manual and from this build's own decisions where a van is not a boat.
1One page, because it was four
The Isotemp has been documented in pieces. The water page carries it across two separate phases, correctly, because plumbing the potable side and splicing the engine coolant are two different days of work. A third page draws all four ports together. A fourth holds the procedure out of the manual. None of them was the thing to hold in your hand in the bay.
This is all of it, in the order you actually do it, with every diagram in line. Nothing on this page is typed twice: the steps, the parts and the drawings are pulled from the same files the rest of the site checks itself against, so if a fitting changes in the BOM it changes here.
The three that bite. The Slim Square's pump limit is 42 psi, not the 55 everyone quotes for the Basic and the Slim. The safety valve must be the lowest point in whatever orientation you mount it. And nothing gets powered until the tank is full.
2Read this before you start
Before anything
- Max pump pressure for the Slim Square is 42 psi, not the 55 the Basic and Slim get. Section 4.4. Your Shurflo shuts off at 55, which is 13 psi over. Measure the actual shutoff and either wind the switch down to about 40 or regulate downstream, BEFORE you pressurise anything.
- The safety valve must be the lowest point in whatever orientation you mount it. The manual says this three separate times.
- No plastic fittings at the heater. Brass or stainless only, because of the heat. The opposite of the nylon-only rule at the tank three feet away.
- Your unit has the factory thermostat mixer, so per Fig. 6 the fresh warm water OUT is 1/2 BSP while cold in and both engine ports are 1/2 NPT. It also means the separate mixing valve on the BOM is redundant.
Red is a warning out of the manufacturer's manual, not advice. Blue is a decision specific to this build, where a van differs from the boat the manual assumes.
3How the coolant loop actually works
Your engine already circulates coolant, pushed by its own water pump. One branch of that circuit runs to the cab heater core behind the dash: coolant goes out, gives up heat to the air blowing over it, and comes back. Two hoses at the firewall, about 3/4 in.
You are splicing your water heater into that branch. Cut each hose, put a reducing tee in, and take a 5/8 line off each. One carries hot coolant out to your heater, the other brings it back. Your unit ends up in parallel with the cab heater, not in series. Both get flow, and neither starves the other. In series you would be restricting the cab heater to feed yours.
Inside the Isotemp the coolant runs through a stainless coil immersed in your fresh water. Heat passes through the coil wall. The two never touch. That is the whole trick: engine heat, no contamination, no extra fuel burned.
So when you drive, the engine reaches about 90 C, the coolant carries that to the coil, and your 4.2 gallons climbs toward it. Park up after a few hours on the road and you have a tank of genuinely hot water you did not pay for. The 120 V element does the same job when you are stationary on shore power.
Why the valves sit at the engine end. With one on each branch right after the tees, you shut both and your water heater is isolated while the cab heater keeps working normally. Put them at the heater instead and the long run stays live, and you would still have to drain the cooling system to touch the tees.
Why airlocks matter so much here. The run goes down through the floor, along under the truck, and back up at the firewall. Air collects at the high points. Air does not carry heat and it blocks flow, so a trapped bubble means the coil never gets hot and the symptom is identical to a broken heater. That is why you raise and lower the hoses to work air out BEFORE clamping them down, and why you bleed on first fill.
Why the coolant drops after the first run. You have just added 30 to 40 ft of 5/8 hose plus the coil to a closed system. That volume has to come from somewhere, and it comes from the header tank. Top it up after the engine has run and the thermostat has opened, or you will pull air in and be back to the airlock problem.
OPEN, as of 2026-09-19: series or parallel. Everything below and the drawing with it assume PARALLEL, two tees, one on each cab heater hose. FarOutRide's Transit install cuts once instead, into the heater hose between the cab heater core and the water pump return inlet, putting the heater in SERIES, and cites Ford for it. Both are done in the field and it is not a decision you revisit cheaply once the hoses are cut. Settle it against the Ford Body Builder guidance first. Section 8 has the detail.
4The second port is the SAFETY VALVE, not a second cold inlet
SETTLED 2026-09-18 off the manufacturer's drawing 001018, the Slim Square with the thermostat mixer, which is your variant. Read at 600 dpi because at page size it is a smudge.
There is ONE fresh cold water in. The drawing labels exactly one, and it points at a tee at the bottom of the unit. Everything else on that tee is factory: the safety valve screws into one branch, and a braided hose runs from the same tee up to the mixer at the top, which is how the mixer gets cold to blend with.
So the thing that has looked like a second cold port for two weeks is the safety valve. That also answers the other open question, because the valve's discharge is exactly where the 3/8 waste hose goes. The drawing shows it curling out from underneath that same body.
What this changes. You make TWO potable connections, not three: fresh cold water IN at the bottom tee, 1/2 NPT outside thread, and fresh warm water OUT at the top, 1/2 BSP outside thread because it leaves from the mixer body. The engine ports are the other two, 1/2 NPT, in the middle of the same face.
Cold IN fills the tank. That water sits against the coil and gets heated to roughly whatever the engine is running at, near 90 C, which is hot enough to scald in well under a second. The factory mixer is what stands between that and the galley tap, and it blends with cold from that same tee through the braided hose.
How this went wrong, since it is worth knowing. The manual puts the mixer and non-mixer variants side by side on one page. Read as one machine it looks like a unit with a spare cold port, and this build carried a third swivel union and a cold tee for a fortnight on that reading. Jeff killed it by standing in front of the thing and saying the angles made no sense.
And the warm outlet is not just an outlet. The manual notes it also VENTS the heater. Dead-end it and you have a sealed vessel being heated, so it must run to a tap.
The separate thermostatic mixing valve that used to sit in this run is gone. The unit has the factory mixer inside it, which is what the Temp knob on the end is, so the blend leg now goes into the unit rather than into a valve in front of it. It was drawn wrong for five days.
5The potable side
Every part at the unit, potable and coolant both, so the list in your hand matches the thing in front of you rather than the build day it belongs to.
| id | part | where |
|---|---|---|
| H1 | 1/2 in PEX ball valve, brass | heater · cold IN to the heater |
| H2 | 1/2 in FNPT swivel to PEX union | cold in |
| H3 | 1/2 in FNPT swivel to PEX union | hot out |
| H4 | 1/2 in PEX ball valve, brass | heater · hot OUT of the heater |
| H6 | 1/2 in PEX ball valve, brass | heater · the bypass bridge |
| H7 | 3/8 in hose for the safety valve outlet | Isotemp spec: 3/8 in (10 mm) hose to a FREE outlet at a lower point, gravity only |
| H8 | 5/8 in heater hose, 210 F, antifreeze rated | 50 ft, plus 15 ft in the extra-long kit and 1 ft of 3/4 for the Transit |
| H9 | Brass barb reducing tees, 3/4 x 3/4 x 5/8 in | Two, and the packing list calls them 3/4 x 5/8 barb reducing tees |
| H10 | 5/8 in ball valves, brass | Two 5/8 brass barb ball valves |
| H11 | 1/2 in NPT male to 5/8 in barb adapters, brass | Two, and the list says 5/8 barb to 1/2 FEMALE NPT, which independently confirms the Fig. 6 correction from BSPP to NPT |
Brass or stainless at the heater, all of it, because of the heat. That is the exact opposite of the nylon-only rule at the tank three feet away, where the moulded tank threads are the fragile thing and a brass fitting is what cracks them. Two opposite rules, one bay.
6The procedure
1 · Position and mount
- The manual permits standing, laying flat, or the angled positions in Fig. 7. Ours lies ON EDGE, long axis fore and aft, which is in the “other positions” bucket. What governs is the safety valve being lowest.
- Find the safety valve on the unit first, then decide which end the gable faces. The valve has to end up low AND over somewhere you can legally drill. Crossmembers decide this, not convenience.
- The manual prefers 30 cm (1 ft) of free space in front for service. The core pocket gives 9 3/4 after the re-measure, which is close. That is why it is a lift-out on unions rather than a fixed install.
- Test the lift-out dry, before you drill. 1 3/4 of headroom and 9 3/4 in front. If you cannot get it out empty, you will never get it out full.
- Mount to the 8020, not to panel. It is about 30 lb dry and close to 70 wet, on washboard.
2 · Fresh water connections
- Cold in and warm out each take a swivel union. The gasket seals, not the thread, and the union is what makes it a lift-out. BRASS.
- ONE cold connection, not two. SETTLED 2026-09-18 off drawing 001018: the bottom of the unit is a TEE carrying your cold supply, the SAFETY VALVE on one branch, and a factory braided hose up to the mixer. The thing that looks like a second cold port is the safety valve.
- Which is also where the drain hose goes. The valve's discharge is on that same body, underneath, and the drawing shows the waste hose curling out of it. 3/8 hose, push on, clamp, run downhill.
- Set the tempering valve between 38 and 65 C / 100 and 150 F.
- The hot outlet also vents the heater, so it must run to a mixer tap. Do not dead-end it.
- Hot water is as hot as the engine. Scalding risk. The manual says so plainly; the mixer is what stands between that and the galley tap.
3 · Coolant loop
- Minimum 5/8 in / 16 mm hose and adaptors, to avoid restricting flow. Flow through the heater must be at least 2 litres/min.
- SERIES OR PARALLEL IS NOT SETTLED. This page has said parallel since the start: tap BOTH cab heater hoses with reducing tees, one on the supply and one on the return, so neither the cab heater nor the water heater starves the other. FarOutRide's Transit install does it differently and cites Ford: ONE cut, into the heater hose between the cab heater core and the water pump return inlet, putting the Isotemp in SERIES on the return leg. Read the note below before you cut anything.
- Isolation valves go at the ENGINE end, just after the tees. That is what lets you isolate the water heater while the cab heater keeps working. Not at the heater. NOTE: if you go SERIES, two plain ball valves would shut the cab heater off with it, which is why FarOutRide used a 4-PORT BYPASS valve instead: it closes the branch and completes the cab circuit in one handle.
- Support the run every 12 to 18 in and insulate both legs. Where you cannot get away from the exhaust, FarOutRide used aluminised heat sleeve and stainless zip ties rather than just routing round it.
- Re-torque every worm clamp after the first few heat cycles. Rubber takes a compression set and the clamps go loose. Not in the manual, learned the hard way by someone else.
- Motorcraft Yellow only, Ford spec WSS-M97B57-A2, and mix concentrate with DISTILLED water, never tap. Never mix coolant types.
4 · The safety valve drain
- 3/8 in hose to a FREE outlet at a lower point. Gravity only. “There must be no valves or skin fittings fitted to the waste water hose.” Section 4.4. That is not advice.
- It is meant to drip. “A small quantity of water can drain from the relief valve when the tank is heated. The water expands during heating. This is a normal situation and indicates the system works properly.” So site the outlet somewhere a regular drip is fine.
- Give it more fall than looks necessary. You will not always park level.
5 · Electrical, and it goes LAST
- DO NOT POWER THE ELEMENT UNTIL THE TANK IS FULL. Dry-firing destroys it. The manual puts this at the end of commissioning for a reason.
- 115 V, 750 W. Wiring per Fig. 8: N white, L black, earth yellow.
- The circuit must have a ground-fault interrupter. Manual requirement, and you are putting it in a bay with 41 gallons of water.
- Working thermostat is 75 C / 167 F. A double overheat protector sits at 96 C / 205 F and is manually reset by pressing a small knob on top.
- Always unplug before removing the connection cover. Slim Square: 3 screws.
6 · Commissioning, in this order
- Fill the tank. Run the pump and open a hot tap so air bleeds out of the hoses and plumbing. Leave it open until it runs solid.
- Test the safety valve. Yours is the BLACK TWIST KNOB version, not the lever one: turn the knob anticlockwise one snap and water should flow into the drain hose, which also proves the hose is not blocked. One further step anticlockwise closes it again. Check which way you left it.
- Start the engine and check coolant circulates.
- Top up the coolant. The loop ADDS volume, so the header tank will be down after the first run. Do not skip this.
- Clear air locks. Raise and lower the connecting hoses to work air out BEFORE you clamp them down for good. An airlock stops circulation completely and looks exactly like a heater that does not work.
- Only now, plug in and switch on. Check operation.
Winterising
- Take off the hot water hose, or take the air bleeder screw on the mixing valve out completely (Fig. 9).
- Open the drain by turning the black knob on the safety valve anticlockwise one snap. One further step anticlockwise closes it again.
- Then RV antifreeze through the system. Your tank has no drain leg, so the pump empties it through the taps and antifreeze does the rest.
7Its three holes in the floor
The Isotemp owns three of the build's 15 floor penetrations, and all three are in the first tier, the ones that get drilled before anything is finished over: Isotemp safety valve drain at 3/8, and the coolant supply and return at 5/8 each. They are three separate holes. Nothing here shares a sleeve.
The safety valve drain goes through the floor, on its own
It is not optional and it is not a bay drain. The manual is explicit: 3/8 hose to a free outlet at a lower point, gravity only, and no valve and no fitting anywhere in it. It also weeps a little every time the tank heats, which is the valve working rather than failing, so it has to end up somewhere outside where a regular drip is fine: not onto a step, not onto the exhaust, not into the bay.
That is why the drain hole cannot be sited until the unit is: the valve has to be the low point of the unit, and the hole has to be under the valve with continuous fall all the way. Mark it with the heater sitting in its place, not off a drawing.
The two coolant holes
One each, supply and return, straight down, at least a couple of inches apart so the potted rings stay separate and each hose can be clamped on its own below. Drill them vertical and let the hose make its turn underneath on a wide radius. A tight bend at the floor is where a heater hose kinks, and a kinked coolant line reads exactly like a heater that does not work.
Pass the bare hose through and butt the foam insulation up to the grommet on both faces. It keeps the hole small, it lets the grommet actually grip the hose, and the insulation still covers the run that matters, which is the length under the truck.
The hole itself, which is the part that bites
The floor is a sandwich, and Jeff taped it on 2026-09-16: 3/4 in original wood deck, 1 in XPS, 1/2 in ply on top, 2 1/4 in all in. Drill a hole and tighten anything against it and that foam band crushes until the fitting is loose, and any weep wicks sideways through it. That is how a composite floor delaminates quietly, a year later, nowhere near the hole.
2 1/4 in is deeper than a standard hole saw cuts. Most bi-metal saws bottom out around 1 1/2. Take the pilot bit right through first, cut from inside until the saw stops, then finish from underneath with the pilot running in the hole you already made. Two cuts, one hole, and they meet.
So every penetration on this build gets potted, which is standard marine practice for through-bolting a cored panel, and it is five steps:
- Pilot from inside, then go and look underneath. 1/8 in, and check what is below before the hole saw comes out: crossmembers, the fuel tank, brake and fuel lines, wiring, exhaust. This is the step that is annoying to do and expensive to skip.
- Cut the hole to the grommet, not to the hose. The white pass-throughs in the kit set the size, so measure one and match the saw to it. Slow speed, steady pressure, from inside.
- Rake the foam back about 1/2 in all round, through the 1 in XPS band only, with a bent nail in a drill or a hook tool. You are making a doughnut-shaped cavity between the ply above and the deck below. Leave both of those alone.
- Tape the underside and fill the cavity with thickened epoxy (West System Six10 thickened epoxy, 190 ml cartridge). Let it cure, then re-drill the hole through the middle of the plug. The penetration now passes through solid epoxy: nothing to crush, and no path to wick along.
- Bed the grommet in sealant (Sikaflex 291) rather than trusting the plastic to seal, seat it, and pass the hose. Then clamp the hose to something solid within a foot below the floor, so road movement pulls on the clamp and not on the grommet.
If your white pass-throughs come apart into two halves that meet in the middle, they are made for exactly this and the two halves land one on each face. If they are a single press-in ring, they still work, but the sealant is doing the sealing and the ring is only protecting the hose from the edge. Either way the epoxy is what makes the hole sound, not the plastic.
8What another build found, and where it disagrees with this one
LOGGED 2026-09-19 from FarOutRide's Isotemp install on a Ford Transit, faroutride.com/isotemp-water-heater. Different model, the Spa 15L rather than the Slim Square 16, but the same heater family in the same van, which makes it the closest thing to a second opinion this build has.
The disagreement that matters: SERIES vs PARALLEL. This page has said parallel from the start, two tees, one on each cab heater hose. They cut ONCE, into the heater hose between the cab heater core and the water pump return inlet, putting the Isotemp in series on the return, and they say that is per Ford. Both are done in the field. Series is one cut and less plumbing, and it feeds the water heater coolant that has already given some heat to the cab. Parallel is two cuts and neither circuit starves the other. UNRESOLVED, and it is worth settling against the Ford Body Builder guidance before anything is cut, because it is not a decision you revisit cheaply.
It also changes the valve. In parallel, two plain ball valves isolate the branch and the cab heater carries on. In series, those same two valves would shut the cab heater off too, which is why they fitted a 4-port bypass valve: one handle closes the branch and completes the cab circuit. So the valve choice follows the series or parallel decision rather than being a separate one.
The gotcha nobody else mentions: their thermal fuse trips FREQUENTLY once engine coolant is in the loop, and the reset is buried behind the cover. They drilled the cover with a 25/64 bit and relocated the reset button so it could be pressed without stripping the unit. Worth knowing before it happens at the wrong moment.
Coolant volume, which corroborates ours: they added about 3.4 L of hose plus 0.5 L in the exchanger, which exceeds Ford's 10 per cent guideline and worked anyway. Our gallon estimate is the same ballpark.
Energy, which this build had no numbers for at all. 980 Wh at the plug to heat 15 L from cold, taking 1 hour 21 minutes. Holding it hot with no use costs about 1386 Wh a day. Over a real seven day trip with periodic heating and some showers they averaged about 975 Wh a day, roughly 30 per cent less than leaving it hot. That is a meaningful load against the battery bank and it argues for heating on demand rather than holding temperature.
Where their numbers do NOT transfer: their pump limit is 55 psi and their safety valve is 6 bar, because the Spa is a different model. Ours is the Slim Square, whose manual says 42 psi. Take the lower one.
Two materials worth stealing: Loctite 577 on the metal thread at the tank, and NBR elastomeric pipe insulation on the coolant hose inside the cabinet.
Source: faroutride.com/isotemp-water-heater, logged 2026-09-19. A Spa 15L rather than a Slim Square 16, so the model-specific numbers do not transfer, but it is the same heater family in the same van.
The kit's own guide says parallel. Vanlife Outfitters' instructions, the ones that came in the box, tee BOTH heater hoses, and their bleeding tip says the cab heater loop and the water heater loop split the pump's pressure between them. So the parts in hand are built for parallel, which is what this page draws. The full guide, transcribed, with the places Tope departs from it: the kit's install guide, and the same steps as a checklist to work through: the interactive install manual.
9What is still open
Two things on this page are decided and one is not. The unit's position in the core pocket is set, on edge with the safety valve low, and the coolant routing is set, down through the floor and forward under the truck. What is not set is where the floor gets drilled, and that waits on a tape rather than on a drawing: the bay's clear depth in front of the unit came back at 9 3/4 in on the re-measure, which is under the foot the manual would like for service, and that is why the whole thing hangs on unions.
Test the lift-out dry, empty, before anything is drilled. It is about 30 lb dry and close to 70 wet. If it will not come out empty it will never come out full, and the first time you need it out will be the time something is leaking.
10Every part named on this page
Tap or hover any id in the text or on any drawing and it will tell you what it is. This is the same thing as a list, for when you want to read it all at once.
| id | part | where |
|---|---|---|
| H1 | 1/2 in PEX ball valve, brass | heater · cold IN to the heater |
| H2 | 1/2 in FNPT swivel to PEX union | cold in |
| H3 | 1/2 in FNPT swivel to PEX union | hot out |
| H4 | 1/2 in PEX ball valve, brass | heater · hot OUT of the heater |
| H6 | 1/2 in PEX ball valve, brass | heater · the bypass bridge |
| H7 | 3/8 in hose for the safety valve outlet | Isotemp spec: 3/8 in (10 mm) hose to a FREE outlet at a lower point, gravity only |
| H8 | 5/8 in heater hose, 210 F, antifreeze rated | 50 ft, plus 15 ft in the extra-long kit and 1 ft of 3/4 for the Transit |
| H9 | Brass barb reducing tees, 3/4 x 3/4 x 5/8 in | Two, and the packing list calls them 3/4 x 5/8 barb reducing tees |
| H10 | 5/8 in ball valves, brass | Two 5/8 brass barb ball valves |
| H11 | 1/2 in NPT male to 5/8 in barb adapters, brass | Two, and the list says 5/8 barb to 1/2 FEMALE NPT, which independently confirms the Fig. 6 correction from BSPP to NPT |
| H12 | Engine coolant, Ford spec | The loop ADDS volume, so the header tank needs topping up after the first run or it will pull air |
| H13 | Hose insulation for the coolant run | One roll of foam pipe insulation |
Ids are the build's own numbering, not a manufacturer's. They are stable: 12 of them appear on this page and every one is the same part on the water system entry and on the buy list.