TopeLeave about Dec 1
← Plumbing build 1/28
← Plumbing

Plumbing build

Water system: fresh, hot, grey, fill28 steps

The whole water system in the order you build it: floor holes, tank fittings, pump, the Isotemp and its coolant loop, the two PEX trunks, galley, both showers, the fill box and the grey side, then the pressure test and winterising.

Where it stands, 2026-09-30Settled: trunk and branch (no manifolds), 1/2 PEX-B with copper CRIMP rings (Jeff owns the tool), nylon at the tank and brass at the heater, the vent is also the overflow at 3/4, gravity leg bagged as a backup, no tank drain (deleted 2026-09-11; T35 caps the tee), no city water inlet, grey fails to ground, coolant loop in PARALLEL per the Vanlife Outfitters kit guide.Have: tank (placed, nothing installed), Shurflo 4008 pump and 182-200 accumulator, Isotemp Slim Square 16, iSpring RO500AK, the Vanlife coolant kit (H8 to H13), the McMaster tank fittings (order 0730JBEREZNY), and three Home Depot plumbing runs (Sept 11, 14, 15): about 45 ft of PEX in sticks, 25 tees, 40 elbows, 16 PEX ball valves, 100 crimp rings, the main and pump valves, two straight stops. H-1 is CUT (2026-09-19).Wrong parts in hand: every swivel adapter bought so far is PLASTIC (PLS on three receipts). Fine at the tank, wrong at the heater. Buy three brass UC526LFA before step 15. The 09-15 swivel elbows say PEX-A: check for barb ridges before crimping them.Open: where the hole patch and the tank sit in the bay (not taped), bay clear height (20 or 18 1/2), pump group stacked or side by side, the pump pressure against the heater's limit (42 psi on one page, 60 on another), the outdoor shower valve, the grey tank and diverter, the level sender, the RO reject outlet. Everything the drawing places on a guess says ASSUMED when you click it.
Order list29 now, 11 after a check, 6 not yet

Prices as last seen; check before paying. "After a check" names the check in the step list.

Order now29

Order now$3.86 ea (listing)
SharkBite UC526LFA brass swivel, 1/2 PEX barb x 1/2 FNPT

THE fix for the plastic swivels: H2 cold in, H3 hot out, and the safety valve drain. Brass, lead-free, crimp ring.

Order now$30.65 (receipt)
Copper crimp rings, 1/2 in, 100

You have 100; the fitting count is about 130. Buy one more jar.

Order now$8.66 (listing, showed out of stock)
SharkBite 23080 crimp go/no-go gauge

Every crimp gets gauged. A ring a few thou open weeps months later behind a panel.

Order now$6.55 (listing)
Everbilt 1/2 in MIP brass plug, 802149

T35: caps the tee's spare port where the tank drain used to be.

Order now$6.57 (listing)
Everbilt 1/2 in barb x 1/2 in MIP brass adapter, 800189

T33: into the inlet of the main valve, on the bench. The 6 in hose slides onto it.

Order now
Shurflo 255-313 strainer

P3, on the pump inlet. Not fitted, not bought (the bay photos fooled us once).

1 · Amazon
Order now
Shurflo 94-591-01 pump silencing kit

P4 and P7: flex hose on both pump ports.

1 · Amazon
Order now
Wingnut swivel, straight, 1/2 FNPT x 1/2 FNPT

P5 and P8: hand-tight on the pump ports, so it lifts out.

Order now
Rubber isolation mounts, McMaster 9376K22

P6, under the pump feet.

1 set · McMaster-Carr
Order now
Accumulator strap

P11: stainless strap or two cushioned clamps into the 8020. Size to the bottle (about 4 3/4 across).

Order now
SharkBite Talon PEX clamps, 1/2 in

D8: within 6 in of every fitting, then every 24 in (18 in on washboard is better).

Order now
Line and valve labels

D10: label both trunks and every valve, with what is normal (open or shut).

1 set · Amazon
Order now
1 1/4 in PVC Sch 40, 2 ft

Sleeves for H-4, H-5 and H-8, 3 in each.

Order now$4.51 ea (listing)
Southland 1 in x 6 in galvanised nipple, 565-060HN

Sleeves for the two coolant holes: metal, the hose runs near 190 F.

Order now
Permatex High-Temp Red RTV, 3 oz

The annulus on H-2 and H-3 only. Sikaflex is rated to about 194 F.

Order now
Sikaflex 291

Beds the other sleeves, both faces.

1 · Amazon
Order now$3.93 (listing)
M-D 3/8 in foam backer rod, 20 ft, 71464

Down each annulus before sealing, so the bead sits in the top 1/2 in.

Order now
Everbilt 1 in x 3 ft aluminium angle, 1/8

Bolted under the patch as the rail every P-clamp hangs from.

Order now
Cushioned P-clamps, stainless, assortment

One per line below the floor: 1 in x4, 3/4 x2, 5/8 x1. Plus three for the vent in the bay (T17).

1 pack · Amazon (search)
Order now
Stainless mesh screen

T16, on the vent outlet, pointing down. Mud daubers nest in open tubes.

1 · Amazon
Order now$12.50 (listing)
Camco 5/8 in x 25 ft drinking water hose, 22783

F13. NSF, lead-free. A garden hose makes the tank taste of it.

Order now
RV pressure regulator with gauge

F11, on the spigot, set 20 to 25 psi.

1 · Amazon
Order now
Hose-end sediment filter, steel mesh

F12. Sediment only, never carbon.

1 · Amazon
Order now
Garden hose flow restrictor washer, about 4 GPM

F26, Jeff's call 2026-09-17: the fill can never beat the vent. Replaces the relief valve.

Order now
SharkBite 24612LF ball valve with drain, 1/2 PEX

S6: the low-point drains at the foot of the shower risers.

Order now
HepvO waterless trap, 1 1/2 in (sink)

G6. No water seal to slosh out on washboard.

1 · Amazon
Order now
Sink strainer basket

G5. Grease congeals in a cold underfloor line.

1 · Amazon
Order now$160.65
Scandvik Aqua Fina 14140 (indoor shower)

S1. Ordered from the shower guide; one order covers both guides.

Order now
Armaflex 1/2 in pipe wrap

S13, the outdoor branch below the floor.

After a check11

After a check$33.30 (listing)
SharkBite U860R100 red PEX-B, 1/2 x 100 ft

Hot side. Sticks in hand cover about 25 ft; the drawn hot runs come to about 31 ft. Buy after the string mockup (step 5).

After a check
SharkBite U860B100 blue PEX-B, 1/2 x 100 ft

Cold side, about 32 ft drawn against 20 ft of sticks. Same check.

After a check$14.97 (listing)
Milwaukee 1 3/8 in hole saw, 49-56-9615

H-2 and H-3. Jeff has not said he owns one. Check the drawer first.

Or: Diablo DHS1375, $10.97 listingCheaper, same size
After a check
3/4 in PVC Sch 40, 2 ft

Sleeves for H-6 and H-7. Check for the offcut from H-1's sleeve first.

After a check
Motorcraft Yellow VC-13DL-G, prediluted, 1 gal

H12, to top up after the loop adds about a gallon. Two pages disagree (orange vs yellow): read the coolant cap or the 2025 book, and never mix types.

After a check
PEX cutter

D9. Check whether one came with the crimp tool.

After a check
Galley faucet

G4. If you already have the faucet, check its shanks: the straight stops give 3/8 OD compression.

After a check
Duckbill valve, 1 in

H-8 outlet: water out, road spray in never. H-8 is not settled; buy if it is drilled.

After a check
Outdoor shower valve and wand

S7. Check it fits the Buyers box wall and its depth before buying.

1 · Amazon
After a check
Trident 161 reinforced line, 1/2 in

S12, the outdoor legs below the floor. Length after the route is marked.

~8 ft · Defender
After a check
RO faucet

R2. Probably in the iSpring box. Open it first.

1 · iSpring

Have it9

Have it$137.95
Class A Customs T-4100 fresh tank, 41 gal

Bought 2026-06-15, placed in the bay. Ports: fill top-left 1 1/2, vent top-right 1/2, out bottom-left 1/2, bottom-right 1 1/2 stays SEALED. Plastic fittings only in its threads (vendor).

Have it
Shurflo 4008-101-A65 pump and 182-200 accumulator

Owned. Confirm the one going on the pressure side is the one whose switch you check in step 13.

1 each · Amazon
Have it$1,277.92
Isotemp Slim Square 16, 4.2 gal, factory thermostat mixer

Owned. The mixer variant: hot out is 1/2 BSP, cold in and both engine ports are 1/2 NPT (Fig. 6).

Have it
Vanlife Outfitters coolant kit: H8 hose, H9 tees, H10 valves, H11 barbs, H13 insulation

In hand, from the packing list 2026-09-11. Do not buy these. Check the insulation length against about 35 ft.

Have it$633.60
iSpring RO500AK-ORB

Owned. Open the box for the RO faucet (R2) before buying one.

1 · iSpring
Have it$172.52
McMaster order 0730JBEREZNY: the tank fittings

T1 to T4, T6 to T10, T13, T14, the 3/4 Trident hose (fill and vent), PTFE tape, paste, stainless clamps.

18 lines · McMaster-Carr
Have it$520.83
Home Depot plumbing runs, 2026-09-11, 09-14, 09-15

PEX sticks (about 25 ft red, 20 ft blue), tees 25, elbows 40, 16 brass PEX ball valves, 100 crimp rings, 7 male adapters, brass nipples, three 1/2 FIP ball valves (T19, P10, spare), nylon barbs (T18), two 1/2 PEX x 3/8 OD straight stops (the galley), 3/4 x 1/2 tubing, pipe insulation. Three receipts in receipts/README.md.

Have it
PEX crimp tool

Jeff owns one; that is why the build is crimp, not cinch.

Have it
Hole saws 1, 1 1/4 and 2 in

Owned. Cover H-4, H-5, H-8 (2 in) and H-6, H-7 (1 1/4).

Not yet6

Not yet
Fill module: transfer pump F18, swivels, mounts, tee, check valve, bibb, cap, cam-lock, wand, foot valve, switch, fused feed

Phase 6 on the water page, deliberately out of the first pass. Not needed to move water: fill through the bibb or the 1 1/2 port.

Not yet
Grey tank W3 and diverter W2

Tank not chosen (15 to 20 gal); the diverter needs 12 V, full port, manual override and feedback, and nothing has all four.

Not yet
Grey line, vent, dump valve, sensor, straps (W1, W4 to W7)

After the tank is chosen.

Not yet
KUS reed float sender, 15 in, 240-33 ohm

T26. The translucent tank reads by flashlight meanwhile. Check the 4 in over the tank for the gland and cable first.

1 · Amazon
Not yet
Thermostatic mixing valve

H5. Very likely redundant: the unit has the factory mixer. Delete it once you confirm the factory one is thermostatic.

Not yet
Road spares: push-fit slip couplings, caps, a valve, the clip

M8 to M14. After the system runs.

Cut list16 parts

Inches. "Field-fit" means cut to the thing it meets, on the day.

partstockqtysize
Cold trunk + branches1/2 PEX-B blue1~32 ft totalcut each leg to the string mockup, not to this drawing
Hot trunk + branches1/2 PEX-B red1~31 ft totalsame
Suction run, tank tee to strainer1/2 PEX-B blue1~19 7/8P1 adapter in the tee, crimp at the strainer
Tank outlet hose1/2 reinforced potable hose16T32: the one part nothing can shut off. Keep it short, double clamp
Fill leg3/4 Trident 1621~4 ftT13 barb to F6 elbow in the box, one piece through the H-5 sleeve
Vent3/4 Trident 1621~4 ftT14 up, then falling all the way; last piece below the floor sleeved or opaque
Safety valve drain1/2 PEX1~19cut at an angle just under the H-1 sleeve, nothing on the end
Coolant supply5/8 heater hose (kit)1~25 ftincludes about 8 ft from the box front to the firewall, ASSUMED
Coolant return5/8 heater hose (kit)1~25 ftthe kit has 50 ft plus 15; check both legs fit
Sleeves H-4, H-5, H-81 1/4 PVC Sch 40331/4 proud above, 1/2 below; H-8 flush at the top
Sleeves H-6, H-73/4 PVC Sch 4023scuff and wipe with alcohol before bedding
Sleeves H-2, H-31 in galvanised nipple26 as boughtor cut to 3; metal for the heat
Clamp rail under the patch1 in aluminium angle112bolted under the patch, clear of the strut
Galley risers1/2 PEX2~35 3/4straight stop at the bottom, 3/8 supply to the faucet
Shower risers1/2 PEX2~51valves S2 / S3 low in the galley cabinet, S6 drains at the foot
Suction wand (held)1/2 PEX offcut120bevel the bottom at 45 degrees

Order and checksteps 1 to 5

    1. Brass first: three SharkBite UC526LFA swivels for the heater (cold in, hot out, safety drain). Every swivel bought so far is plastic.
    2. Pump group: Shurflo 255-313 strainer, the 94-591-01 silencing kit, two wingnut swivels, McMaster 9376K22 mounts, an accumulator strap.
    3. One more jar of 1/2 copper crimp rings and a go/no-go gauge. Brass plug 802149 for T35 and barb 800189 for T33.
    4. Floor: 1 1/4 PVC, two 1 in galvanised nipples, red RTV, Sikaflex 291, backer rod, the 1 in aluminium angle, P-clamps.
    5. Fill kit for the first test: drinking hose, regulator, sediment filter, a 4 GPM restrictor washer.
    6. Home Depot #4013 has most of it. Aisles unknown: put the internet number in the app with the store set.
    Tip Hold the PEX coils until the string mockup (step 5). Sticks in hand may be enough for the first stage.
    1. Lay out the three Home Depot runs and the McMaster box. Tick each against the order list.
    2. Plastic swivels (marked PLS): keep them for cold joints only. Never at the heater.
    3. The two swivel ELBOWS from 09-15 say PEX-A. Look for barb ridges. If they are smooth F1960 expansion fittings, they will not take a crimp ring: return them.
    4. The 3/4 x 1/2 tubing from 09-14: confirm it is FDA or food grade before it touches drinking water.
    5. Vanlife kit: two reducing tees, two 5/8 valves, two barbs, hose, insulation. Measure the insulation roll.
    Caution A PEX-A expansion fitting crimped with a copper ring looks finished and is not.
    1. Bay clear height: is 18 1/2 to the lid or to a rail? It decides the heater lift-out.
    2. Where the tank sits: gap on each side, and which way its ported face points. The page puts the ports facing the pocket.
    3. Where the 6 x 12 hole patch sits from the bench front and from the passenger wall. The page assumes 125 aft, 50 across.
    4. Under the truck: the passenger frame rail, the strut and crossmember by the patch, the exhaust, and the Buyers box wall thickness.
    5. The pump's real shutoff: run it against a shut tap with a gauge. You need this number for step 13.
    Caution A phone scan is not a dimension. Tape it.
    1. Isotemp on edge against the crossways bulkhead, gable toward the tank: 7 1/4 x 23 1/4 x 16 3/4 tall.
    2. About 9 3/4 in of gable clearance. Check you can reach the air bleed, the thermostat and the reset with the lid open.
    3. Lift it out empty. If it does not come out empty, it never comes out full.
    4. Pump and accumulator in the strip in front of it: try them side by side and stacked. Side by side is drawn. Pick one.
    5. Find the safety valve: it is the bottom of the cold tee on the gable (drawing 001018). It must be the lowest point.
    Tip Mark where the safety valve plumbs down to the floor. H-1 is already cut there; check it lines up.
    1. Run string where the trunks go: out of the bay along the inside of the bench front, forward along the driver wall at floor level, behind the Happijac column, into the galley cabinet.
    2. Mark every tee: heater, outdoor shower, RO, galley, indoor shower.
    3. Measure the string. The drawing gets about 32 ft cold and 31 ft hot with branches. Buy coils if the sticks fall short.
    4. Count fittings off the string: a tee takes 3 rings, an elbow or coupling 2, every adapter or valve end 1.
    Tip Every tee and valve must land in a cabinet or a bay you can open. Nothing joins behind microcement.

Floorsteps 6 to 7

    1. H-1 is cut. Seven to go, in your order: front row from the centre out, then the rear row back.
    2. Saws: H-2 and H-3 1 3/8, H-4, H-5 and H-8 2 in, H-6 and H-7 1 1/4.
    3. 1/8 pilot first, 12 in long, through the whole floor. Look underneath at the pilot before you commit the saw.
    4. The floor is 2 1/4 thick, deeper than a 1 1/2 saw cuts: cut from the top, then finish from below on the same pilot.
    5. Keep 3/4 between hole edges and 1/2 to the patch edge. H-8 waits until its position is settled (the low point of the bay).
    Caution The Buyers box is aluminium: WD-40 on the saw, not cutting oil, and no steel swarf left in the box.
    1. Cut the sleeves 3 in long: 1/4 proud above, 1/2 below. Scuff with 80 grit and wipe with alcohol.
    2. 1 1/4 PVC in H-4, H-5, H-8 (H-8 flush at the top, in a sealed dish). 3/4 PVC in H-6, H-7. Galvanised nipples in H-2, H-3.
    3. Shim each 2 in sleeve at three points, plumb from two sides. Backer rod down the gap, then gun the top 1/2 in and tool it.
    4. Sikaflex 291 on the PVC sleeves. High-temp red RTV on H-2 and H-3 only.
    5. Bolt the 1 in aluminium angle under the patch as the clamp rail, clear of the strut. Isolate steel bolts from the aluminium.
    Tip A wide gap seals better than a tight one with this method: you can get a nozzle in.

Tanksteps 8 to 11

    1. On the bench, in a vice: T33 brass barb into the inlet of T19 (main valve), T20 nipple, T21 brass tee, T35 plug in the spare port, P1 PEX adapter in the run.
    2. PTFE on the tapered threads, 3 wraps, paste over it on joints you will not touch again.
    3. In the bay: T18 nylon barb into the bottom-left port, hand-tight plus a quarter turn. Nylon only in the tank.
    4. 6 in of reinforced potable hose (T32) from T18 to the bench assembly. Double clamp both barbs.
    5. Main valve normally OPEN. One handle stops everything downstream.
    Caution T32 is the only part that cannot be shut off: a failure there empties 41 gallons into the bay. Keep it 6 in, not 2 ft.
    1. Cut the membrane out of the top-left 1 1/2 port with a razor knife. Do not touch the bottom-right one.
    2. T8 nylon nipple, T7 tee: up branch capped with T1, straight-through branch to T9 bushing, T10 nipple, T11 valve, T12 street elbow pointing down, T13 barb.
    3. 3/4 Trident 162 (F1) down, one piece, through the H-5 sleeve and into the back of the Buyers box. About 4 ft drawn.
    4. T11 stays OPEN. The daily valve is the bibb outside (F7, in the fill module).
    Tip Bag the gravity leg parts (T2 to T5) together where you can find them in the dark.
    1. T14 nylon barb into the top-right 1/2 port. 3/4 Trident hose on it.
    2. Up first, then falling all the way to H-4. No sag, no trap: support every 12 in with T17 P-clamps on the 8020.
    3. Through the H-4 sleeve, ending in free air below the floor, pointing down, with the stainless screen (T16). Never inside the Buyers box.
    4. The part below the floor sees daylight: sleeve it or use opaque 161 hose for that piece.
    Caution The vent is the tank's pressure protection. The vendor warns a sealed pressure fill will split the tank. Blocked vent plus pressure fill is the failure.
    1. KUS reed float, 15 in, through the moulded pad in the middle of the top. Not bought.
    2. The pad is a flat 2 in blank: sand the embossed letters flat so the gasket seals.
    3. Check there is room in the 4 in over the tank for the gland and a cable bend before you buy it.
    4. Meanwhile the tank is translucent: a flashlight on the wall reads the level.

Pumpsteps 12 to 13

    1. Isolation mounts (P6) under the pump feet, screwed to the bay floor or the 8020.
    2. PEX suction run from the outlet tee to the strainer (P3). The strainer goes BEFORE the pump: downstream it does nothing.
    3. Flex hoses (P4, P7) on both pump ports with the wingnut swivels (P5, P8), hand-tight. The pump lifts out without cutting anything.
    4. Wire the pump through its fuse and switch (electrical guide). Do not run it yet.
    Tip Flex hose on both sides plus the mounts is what keeps pump buzz out of the bench and the bed frame.
    1. Check the accumulator's precharge with a tyre gauge before plumbing it. Factory is 30 psi; set it against the pump's restart pressure per the Shurflo 182-200 sheet (check the sheet).
    2. Strap it (P11) into the 8020. It weighs about 2 lb charged and must not hang on its fittings.
    3. P10 ball valve AFTER the accumulator, not between it and the pump. Then the cold header tee.
    4. Pressure check: the Shurflo shuts off at 55 psi. One Isotemp page says the Slim Square limit is 42 psi, another says 60. Read the manual for YOUR unit, and turn the pump switch down if it says 42.
    Caution Do not pressurise the heater until the pump pressure question is settled.

Hot watersteps 14 to 17

    1. On edge, on its adjustable brackets, into the 8020. About 30 lb dry and 70 wet, on washboard.
    2. Gable toward the tank, safety valve at the bottom, the lowest point.
    3. Every connection on a union so it lifts out. Test the lift-out once more with the brackets on.
    4. GFCI outlet for the 120 V element high on the wall (electrical guide). Do NOT plug it in.
    Caution Never power the element until the heater is full of water. Dry-firing kills it.
    1. Brass UC526LFA swivels on cold in (H2) and hot out (H3). The swivel seals on its gasket. Hot out is 1/2 BSP on the mixer unit: if it will not pull down on the gasket, get a BSP swivel.
    2. Threads into the heater: Loctite 577 or Bondline T777, the manual's spec.
    3. Three PEX ball valves: H1 cold in, H4 hot out, H6 the bypass bridge between them. In use: H1 and H4 open, H6 shut.
    4. Set the factory mixer between 100 and 150 F (38 to 65 C).
    5. Run the hot out to the hot trunk. It also vents the heater, so it must end at a tap, never a dead end.
    Caution No plastic at the heater. The swivels from Home Depot so far are all plastic.
    Tip One cold connection only (drawing 001018). What looks like a second cold port is the safety valve.
    1. Brass swivel on the safety valve outlet, 1/2 PEX from it, falling all the way to the H-1 sleeve.
    2. A short stub through the floor, cut at an angle just below the sleeve. Nothing on the end: no cap, no screen, no valve.
    3. Tag it underneath: this drip is normal. It weeps a little on every heat-up.
    4. The exhaust runs under this corner. The stub stays short so it never gets near the pipe.
    Caution No valve and no fitting in that line, ever (manual 4.4).
    1. PARALLEL, per the Vanlife kit's guide: cut BOTH cab heater hoses at the firewall and splice in the two H9 reducing tees. Brass only.
    2. H10 5/8 valves right after the tees, at the engine end. Shut both and the van is back to factory.
    3. 5/8 heater hose (H8) back along the inboard side of the passenger frame rail, clamped every 12 to 18 in, insulated (H13). Aluminised heat sleeve wherever it passes the exhaust.
    4. Up through H-2 and H-3 (bare hose through the metal sleeve, insulation butted to both faces) to the H11 barbs on the engine ports.
    5. Raise and lower the hoses to work the air out before you clamp them down for good.
    Caution Engine off and cold before you cut a hose. Have a drain pan and the coolant ready.
    Tip Re-torque every worm clamp after the first few heat cycles.

Distributionsteps 18 to 22

    1. Cold (blue) from the header tee, hot (red) from H4. Out of the bay along the inside of the bench front, then forward along the driver wall at floor level.
    2. Hot above cold where they run together, so they never touch.
    3. Crimp every joint and gauge every ring. Square cuts only.
    4. Leave a tee for the outdoor shower in the bay, one for the RO and one for the galley under the sink, and run on to the shower risers.
    5. Clamp within 6 in of every fitting, then every 24 in (18 is better on washboard). Label both trunks.
    Caution Copper crimp rings and stainless cinch clamps are different systems. Neither tool closes the other.
    1. Tee off each trunk under the sink. The two straight stops you bought (1/2 PEX x 3/8 OD) are the galley valves AND the faucet connectors.
    2. 3/8 supply lines up to the faucet. Check the faucet's shanks before you buy lines.
    3. Strainer basket (G5) in the sink.
    Tip Shut the two stops and you can take the faucet apart with the rest of the truck live.
    1. Tee off the cold trunk, R1 valve right at the tee. The RO runs whenever it makes water, so it is the branch you most want to kill on its own.
    2. iSpring RO500AK under the counter, beside the sink. Its faucet (R2) is probably in the box.
    3. Reject water: its own outlet through the floor (H-15) is not settled. The fallback is a tee into the grey line upstream of the diverter (R3).
    1. S2 cold and S3 hot valves low in the galley cabinet, where you can reach them. Low-point drain valves (S6) at the foot of each riser.
    2. Up inside the cabinet, through the partition at about 39 and 41 in, along the driver wall cavity to the Scandvik 14140.
    3. The Scandvik comes with 1/2 in male NPT adapters. Its real position comes from the dry-fit in the shower guide (mixer drawn at 40 in, ASSUMED).
    4. Do this before the shower wall is skinned: the shower guide's driver wall step closes it.
    Caution Pressure test this branch (step 26) before wedi goes over it.
    1. Tees in the bay, S8 cold and S9 hot valves INSIDE the heated bay, not in the box.
    2. PEX to just past the valves, then marine reinforced line (S12) down through H-7 and H-6. No push-fit outside.
    3. Into the back of the Buyers box to the shower valve (S7). Insulate the legs below the floor (S13).
    4. S11 drain valve at the true low point of that plumbing.
    Tip The freeze habit: shut S8 and S9, open the valve outside, open S11. The outside leg drains in 30 seconds.

Fill modulestep 23

    1. F3 bulkhead through the box's back wall, with nylon shoulder washers on both faces and a backing plate (F4): brass through aluminium is a galvanic cell.
    2. Inside: F6 elbow, F21 tee. One branch through the F22 check valve to the F7 boiler drain with its F8 cap. The other to the F18 transfer pump on F20 mounts.
    3. F17 cam-lock bulkhead for the suction wand. Deliberately NOT garden hose thread, so a pressurised hose can never meet the pump suction.
    4. F23 drain at the low corner, a drain hole in the box, the F24 switch where you can see the jug, a fused 14 AWG feed (F25), fused at the battery end.
    Tip Until this is built, fill through the bibb leg or pour into the 1 1/2 port.

Greysteps 24 to 25

    1. H-9 under the sink (1 1/2 in). Galley: strainer, G6 HepvO, 1 1/2 line down through H-9.
    2. Shower waste and its HepvO are built in the shower guide (through H-10).
    3. Both fall the whole way to the diverter (W2). It fails to GROUND. The 95 percent full signal returns it to ground too.
    4. Until the diverter and tank are chosen, both lines run straight to ground. Pipe it so the diverter drops in later.
    Caution W2 is the hardest thing left to source: 12 V, 1 1/2 full port, manual override and position feedback. Nothing off the shelf has all four yet.
    1. 15 to 20 gal, underslung, near the sink and shower. Not chosen. The drawing puts it outboard of the driver rail; the floor plan drew it straddling the rail.
    2. On a cradle with straps (W7). Never a full tank on straps alone.
    3. Dump valve (W5) at the low point, level sensor (W6), its own vent (W4) clear of the heater intake.

Commissionsteps 26 to 28

    1. Restrictor washer, regulator at 20 to 25 psi and the sediment filter on the drinking hose. Fill watched, never unattended.
    2. Fill until water comes out of the vent below the floor. That is full.
    3. All taps shut, H6 bypass shut, heater valves open. Pump on: it runs to shutoff and stops.
    4. Walk every joint with a dry paper towel. Then leave it: if the pump restarts on its own with every tap shut, something leaks.
    5. Open each hot tap until the air is out and it runs solid. The heater is now full.
    Caution No 120 V to the heater until the hot taps run solid.
    1. Test the safety valve: black knob anticlockwise one snap, water should come out of the H-1 stub. One more snap closes it. Check how you left it.
    2. Engine on, heater valves (H10) open, feel both hoses warm. Raise and lower them again to clear air.
    3. Top up the coolant after the first run: the loop adds about a gallon. Check again the next morning, cold.
    4. Then plug the element in on the GFCI and check it heats.
    5. Re-torque every coolant clamp after a few heat cycles. Sanitise: about 3/4 cup unscented bleach in 41 gal, every tap until you smell it, 4 to 12 hours, flush. Shut R1 first.
    Caution Bleach destroys an RO membrane. Isolate the RO before you sanitise.
    1. Portland freezes. Every leg below the floor goes first: outdoor shower (S8 and S9 shut, S11 open), fill module drain (F23).
    2. Heater: element off, shut H1 and H4, open H6. Drain it through the safety valve knob, or take the air bleed screw out of the mixer.
    3. Run the tank down through the taps (there is no tank drain). Undo T32's two clamps for the last of it.
    4. RV antifreeze through the pump to every tap, hot and cold, until it runs pink. Open the S6 drains.
    5. Isolate and drain the RO per iSpring.
    Tip Write which valves you shut on a tag on the main valve. In spring you reverse the list.
Notes10
  • Design authority is the water system journal entry (every part, id and reason). This page is the order of work. Holes: floor holes. Heater: Isotemp install and the Vanlife guide. Shower waste and the mixer's wall: shower build. Where things sit: floor plan.
  • ASSUMED on the drawing: where the tank and the core pocket sit in the bay (floor plan's guess, tank face against the pocket); the hole patch at 125 aft, 50 across; which way the tank ports face; the heater against the rear wall with the gable toward the tank; port and engine connection heights on the gable; pump and accumulator side by side; the trunk route; counter height 36; Buyers box depth 18; the passenger frame rail mirrored from the driver one; the grey tank outboard of the driver rail.
  • Pipes are drawn about 1 in thick so they read at this scale. Lengths in the cut list come from the drawn runs plus 15 percent: a starting point, not a cut length.
  • Unknown and blocking: bay clear height (20 on 07-27, 18 1/2 on 09-09, lid or rail?), the patch station, crossmember and strut positions, the exhaust near the heater drain and the Buyers box, the safety valve position against H-1, the outdoor shower valve, the grey tank, the diverter, the RO reject outlet, the 1 3/8 hole saw.
  • Conflict: Isotemp pump pressure. working/isotemp_install.py says the Slim Square limit is 42 psi (section 4.4); dimensions.json says the US manual allows 60 and 42 belongs to the 230 V unit. The Shurflo shuts off at 55. Read the manual that came with this unit.
  • Conflict: coolant colour. The water page links Motorcraft ORANGE; the install page says Motorcraft YELLOW (WSS-M97B57-A2); Ford lists VC-13DL-G yellow for 2015 to 2025 Transits. Check the cap.
  • Conflict: H14, the swivel for 'cold into the mixer', is still on the water page, but drawing 001018 (settled 2026-09-18) shows one cold connection. So two heater swivels, plus one for the safety drain. F5 (cold galvanising primer) was for a steel box; the Buyers box is aluminium.
  • Conflict: the bay axes. The 2026-09-09 note reads the pocket as 'bulkhead to tank face' fore and aft, which puts the tank fore or aft of the heater; the floor plan puts them side by side across the bench. This page follows the floor plan.
  • Conflict: the floor plan draws the grey tank across the driver frame rail. It cannot hang there. Drawn outboard here; place it once the rails are mapped.
  • Electrical is not in this guide: pump fuse and switch, the GFCI for the element, the transfer pump feed. See the electrical pages.