Shower
wedi floor and walls, the swing door to the kitchen, the slider to the cab, microcement.
Prove it, write down what was actually built, and close it out as a journal entry.
Tests
Prove it holds water and survives the road. Tap a test to see what it checks.
Flood test the waterproofing
Plug the drain, fill the base to just under the curb tops, leave it 24 hours. Check underneath, in the cab and behind the wardrobe.
Drain test
Run the shower 10 minutes: the floor drains dry, nothing pools. Park on a slope and repeat.
Door cycles
Open and shut both doors twenty times: no rub, latches catch every time, D1 stops at about 78 degrees.
Washboard road
Drive a rough road with everything latched. Listen for rattles; check the doors, the track stops and the hinge screws after.
Snags
Anything that needs fixing after the tests: tell Claude, or add it in the tracker's notes, and it goes here with the step that fixes it.
As built
The numbers the shower was actually built to, from the tracker. They replace the design numbers everywhere once measured.
Cab wall bolt heads
drawn at about 1/4
as built not yet
Room width at 3 heights
drawn at 52 1/2
as built 52 1/4 at all three heights
Room depth at 3 heights
drawn at 22 3/16
as built 21 1/4 at all three heights (partition built)
Floor diagonals
drawn at
as built 56 and 56: square
80/20 on the driver wall
drawn at
as built faces line up: straight and plumb on the driver side (straightedge)
The cab passthrough
drawn at 27 3/8 x 39, assumed at the wardrobe end
as built 27 1/2 x 39 1/8; starts 1 3/4 behind the wardrobe face (toward the passenger wall), so the wardrobe shows from the cab: that strip needs filling
Upper cab band
drawn at 5/8
as built not yet
Ceiling heights
drawn at 72 to 76 1/4
as built 76 at the kitchen wall, flat about 12 in, then curves down to 70 1/2 at the cab wall
The partition opening
drawn at 21
as built not yet
The fan zone
drawn at 30 from the wardrobe, 66 1/2 up, behind the Pelican box
as built not yet
Wardrobe top and the cubby
drawn at ply ceiling 75 1/2, gap 3 3/8 at the front (Jeff): wardrobe top 72 1/8; 8020 at 76 1/4 behind the ply. Middle and back still to tape
as built not yet
The vinyl
drawn at 1/8
as built about 1/8
Mark the drain
drawn at
as built pilot at 20 from the driver 80/20, 12 1/2 from the cab plywood; below: about 3 in behind the crossmember and 3 in from the frame rail, clear
Where the shower goes
drawn at mixer 40 up
as built not yet
Close it out